Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/121718
Citations
Scopus Web of Science® Altmetric
?
?
Type: Journal article
Title: Blood-based protein biomarkers for diagnosis of Alzheimer disease
Author: Doecke, J.D.
Laws, S.M.
Faux, N.G.
Wilson, W.
Burnham, S.C.
Lam, C.P.
Mondal, A.
Bedo, J.
Bush, A.I.
Brown, B.
De Ruyck, K.
Ellis, K.A.
Fowler, C.
Gupta, V.B.
Head, R.
Macaulay, S.L.
Pertile, K.
Rowe, C.C.
Rembach, A.
Rodrigues, M.
et al.
Citation: Archives of Neurology, 2012; 69(10):1318-1325
Publisher: American Medical Association
Issue Date: 2012
ISSN: 0003-9942
1538-3687
Statement of
Responsibility: 
James D. Doecke, Simon M. Laws, Noel G. Faux, William Wilson, Samantha C. Burnham, Chiou-Peng Lam
Abstract: OBJECTIVE:To identify plasma biomarkers for the diagnosis of Alzheimer disease (AD). DESIGN:Baseline plasma screening of 151 multiplexed analytes combined with targeted biomarker and clinical pathology data. SETTING:General community-based, prospective, longitudinal study of aging. PARTICIPANTS:A total of 754 healthy individuals serving as controls and 207 participants with AD from the Australian Imaging Biomarker and Lifestyle study (AIBL) cohort with identified biomarkers that were validated in 58 healthy controls and 112 individuals with AD from the Alzheimer Disease Neuroimaging Initiative (ADNI) cohort. RESULTS:A biomarker panel was identified that included markers significantly increased (cortisol, pancreatic polypeptide, insulinlike growth factor binding protein 2, β(2) microglobulin, vascular cell adhesion molecule 1, carcinoembryonic antigen, matrix metalloprotein 2, CD40, macrophage inflammatory protein 1α, superoxide dismutase, and homocysteine) and decreased (apolipoprotein E, epidermal growth factor receptor, hemoglobin, calcium, zinc, interleukin 17, and albumin) in AD. Cross-validated accuracy measures from the AIBL cohort reached a mean (SD) of 85% (3.0%) for sensitivity and specificity and 93% (3.0) for the area under the receiver operating characteristic curve. A second validation using the ADNI cohort attained accuracy measures of 80% (3.0%) for sensitivity and specificity and 85% (3.0) for area under the receiver operating characteristic curve. CONCLUSIONS:This study identified a panel of plasma biomarkers that distinguish individuals with AD from cognitively healthy control subjects with high sensitivity and specificity. Cross-validation within the AIBL cohort and further validation within the ADNI cohort provides strong evidence that the identified biomarkers are important for AD diagnosis.
Keywords: Alzheimer's Disease Neuroimaging Initiative
Rights: ©2012 American Medical Association. All rights reserved.
DOI: 10.1001/archneurol.2012.1282
Published version: http://dx.doi.org/10.1001/archneurol.2012.1282
Appears in Collections:Aurora harvest 4
Medicine publications

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.