Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/125019
Citations
Scopus Web of Science® Altmetric
?
?
Type: Journal article
Title: Leadless left ventricular endocardial pacing in nonresponders to conventional cardiac resynchronization therapy
Author: Sidhu, B.S.
Porter, B.
Gould, J.
Sieniewicz, B.
Elliott, M.
Mehta, V.
Delnoy, P.P.H.M.
Deharo, J.-C.
Butter, C.
Seifert, M.
Boersma, L.V.A.
Riahi, S.
James, S.
Turley, A.J.
Aurrichio, A.
Betts, T.R.
Niederer, S.
Sanders, P.
Rinaldi, C.A.
Citation: Pacing and Clinical Electrophysiology, 2020; 43(9):966-973
Publisher: Wiley
Issue Date: 2020
ISSN: 0147-8389
1540-8159
Statement of
Responsibility: 
Baldeep S. Sidhu, Bradley Porter, Justin Gould, Benjamin Sieniewicz, Mark Elliott, Vishal Mehta, Peter P.H.M. Delnoy, Jean-Claude Deharo, Christian Butter, Martin Seifert, Lucas V.A. Boersma, Sam Riahi, Simon James, Andrew J. Turley, Angelo Auricchio, Timothy R. Betts, Steven Niederer, Prashanthan Sanders, Christopher A. Rinaldi
Abstract: Background: Endocardial pacing may be beneficial in patients who fail to improve following conventional epicardial cardiac resynchronization therapy (CRT). The potential to pace anywhere inside the left ventricle thus avoiding myocardial scar and targeting the latest activating segments, may be particularly important. The WiSE-CRT system (EBR systems, California) reliably produces wireless, endocardial left ventricular (LV) pacing. The purpose of this analysis was to determine whether this system improved symptoms or led to LV remodelling in patients who were non-responders to conventional CRT. Method: An international, multicentre registry of patients who were non-responders to conventional CRT and underwent implantation with the WiSE-CRT system was collected. Results: 22 patients were included; 20 patients underwent successful implantation with confirmation of endocardial biventricular pacing and in 2 patients there was failure of electrode capture. 18 patients proceeded to 6-month follow-up; endocardial pacing resulted in a significant reduction in QRS duration compared with intrinsic QRS duration (26.6±24.4ms; P = 0.002) and improvement in left ventricular ejection fraction (LVEF) (4.7±7.9%; P = 0.021). The mean reduction in left ventricular end-diastolic volume was 8.3±42.3cm3 (P = 0.458) and end-systolic volume (LVESV) was 13.1±44.3cm3 (P = 0.271), which were statistically non-significant. Overall, 55.6% of patients had improvement in their clinical composite score and 66.7% had a reduction in LVESV ≥15% and/or absolute improvement in LVEF ≥5%. Conclusion: Non-responders to conventional CRT have few remaining treatment options. We have shown in this high risk patient group, the WiSE-CRT system results in improvement in their clinical composite score and leads to left ventricular remodelling.
Keywords: Cardiac resynchronization therapy; endocardial pacing; WiSE-CRT system
Rights: © 2020 The Authors. Pacing and Clinical Electrophysiology published by Wiley Periodicals, Inc.
DOI: 10.1111/pace.13926
Grant ID: NHMRC
Published version: http://dx.doi.org/10.1111/pace.13926
Appears in Collections:Aurora harvest 4
Medicine publications

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.