Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/133593
Citations
Scopus Web of Science® Altmetric
?
?
Type: Journal article
Title: The application of optical coherence tomography to image subsurface tissue structure of antarctic krill Euphausia Superba
Author: Bellini, N.
Cox, M.J.
Harper, D.J.
Stott, S.R.
Ashok, P.C.
Dholakia, K.
Kawaguchi, S.
King, R.
Horton, T.
Brown, C.T.A.
Citation: PLoS One, 2014; 9(10):e110367-1-e110367-7
Publisher: Public Library of Science (PLoS)
Issue Date: 2014
ISSN: 1932-6203
1932-6203
Editor: Langowski, J.
Statement of
Responsibility: 
Nicola Bellini, Martin J. Cox, Danielle J. Harper, Sebastian R. Stott, Praveen C. Ashok, Kishan Dholakia, So Kawaguchi, Robert King, Tammy Horton, Christian T. A. Brown
Abstract: Many small open ocean animals, such as Antarctic krill, are an important part of marine ecosystems. To discover what will happen to animals such as krill in a changing ocean, experiments are run in aquaria where conditions can be controlled to simulate water characteristics predicted to occur in the future. The response of individual animals to changing water conditions can be hard to observe, and with current observation techniques it is very difficult to follow the progress of an individual animal through its life. Optical coherence tomography (OCT) is an optical imaging technique that allows images at high resolution to be obtained from depths up to a few millimeters inside biological specimens. It is compatible with in vivo imaging and can be used repeatedly on the same specimens. In this work, we show how OCT may be applied to post mortem krill samples and how important physiological data such as shell thickness and estimates of organ volume can be obtained. Using OCT we find an average value for the thickness of krill exoskeleton to be (30±4) µm along a 1 cm length of the animal body. We also show that the technique may be used to provide detailed imagery of the internal structure of a pleopod joint and provide an estimate for the heart volume of (0.73±0.03) mm3.
Keywords: Tomography
Rights: © 2014 Bellini et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited
DOI: 10.1371/journal.pone.0110367
Grant ID: http://purl.org/au-research/grants/arc/FS110200057
Published version: http://dx.doi.org/10.1371/journal.pone.0110367
Appears in Collections:IPAS publications

Files in This Item:
File Description SizeFormat 
hdl_133593.pdfPublished version3.88 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.