Title: Assigning trabecular bone material properties in finite element models simulating the pelvis before and after the development of peri-prosthetic osteolytic lesions
Author: Grace, T.M.
Solomon, L.B.
Atkins, G.J.
Thewlis, D.
Taylor, M.
Citation: Journal of The Mechanical Behavior of Biomedical Materials, 2022; 133:1-13
Publisher: Elsevier BV
Issue Date: 2022
ISSN: 1751-6161
1878-0180
Statement of
Responsibility: 
Thomas M. Grace, Lucian B. Solomon, Gerald J. Atkins, Dominic Thewlis, Mark Taylor
Abstract: Estimating strain distribution in the acetabulum before and after the development of peri-prosthetic osteolytic lesions secondary to total hip arthroplasty may assist with understanding the pathogenesis of this condition. This could be achieved by performing patient-specific finite element analysis of (1) total hip arthroplasty recipients with developed acetabular osteolytic lesions, and (2) models simulating the patient’s pelvis and implant immediately after primary surgery. State of the art patient-specific total hip arthroplasty finite element analysis simulations obtain trabecular bone material properties from Hounsfield units within computed tomography (CT) scans of patients. However, this is not feasible when an implant is already in situ due to metal artefact disruption and, in turn, incorrectly reproduced Hounsfield units. Therefore, alternative methods of assigning trabecular bone material properties within such models were tested and strain results compared. It was found that assigning set material properties throughout the trabecular bone geometry was sufficient for the desired application. Simulating the primary implant and pelvis requires geometric and material based assumptions. Therefore, comparisons were made between strain values obtained from simulated primary models, from state of the art methods using material properties obtained from intact bone within a CT scan, and from models with osteolytic lesions. Strain values found using the finite element models simulating the pelvis before osteolytic lesion developed were considerably closer to those found using state of the art methods than those found for the bone loss models. These models could be used to determine relationships between strain distribution and factors such as bone loss.
Keywords: Peri-prosthetic osteolysis; Finite element analysis; Strain distribution; Acetabulum; Metal artefact
Rights: © 2022 Elsevier Ltd. All rights reserved.
DOI: 10.1016/j.jmbbm.2022.105311
Grant ID: http://purl.org/au-research/grants/nhmrc/1126229
Published version: http://dx.doi.org/10.1016/j.jmbbm.2022.105311
Appears in Collections:Molecular and Biomedical Science publications

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.