Title: Radiographic inguinal curl may indicate paraspinal misplacement of percutaneously inserted central venous catheters: report of three cases
Author: Chedid, F.
Abbas, A.
Morris, L.
Citation: Pediatric Radiology: roentgenology, nuclear medicine, ultrasonics, CT, MRI, 2005; 35(7):684-687
Publisher: Springer-Verlag
Issue Date: 2005
ISSN: 0301-0449
1432-1998
Statement of
Responsibility: 
Faris Chedid, Adil Abbas, Lloyd Morris
Abstract: Background: Misplacement of percutaneously inserted central venous catheters (PCVCs) into the paraspinal venous plexus can result in devastating outcomes. Several cases have been reported in the literature together with an explanation of the mechanism. Objective: To describe three premature babies with their PCVCs inserted through the left saphenous vein that ended up in the lumbar spinal dural venous plexus. Results: Plain radiographs obtained to check positions showed an unusual 360° curl of the PCVC in the left inguinal area. Conclusion: We believe that misplacement of the catheter into the paraspinal venous plexus could be diagnosed with great accuracy if such a curl is seen.
Keywords: Percutaneous central venous catheter
Paraspinal venous plexus
Misplacement
Infant
Description: © Springer-Verlag 2005