Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/7071
Citations
Scopus Web of ScienceĀ® Altmetric
?
?
Type: Journal article
Title: The sensitivity of ultrasound and serum alpha-fetoprotein in population-based antenatal screening for neural tube defects, South Australia 1986-1991
Author: Chan, A.
Robertson, E.
Haan, E.
Ranieri, E.
Keane, R.
Citation: British journal of obstetrics and gynaecology, 1995; 102(5):370-376
Publisher: BLACKWELL SCIENCE LTD
Issue Date: 1995
ISSN: 0306-5456
1471-0528
Abstract: <h4>Objective</h4>To determine the sensitivity of antenatal screening methods for neural tube defects in population-based screening in South Australia in 1986-1991, and whether ultrasound can replace serum alpha-fetoprotein screening in terms of achieving an equivalent level of sensitivity.<h4>Design and setting</h4>Ascertainment of all births and terminations of pregnancy with neural tube defects from multiple sources for 1986-1991 in South Australia. Serum and amniotic fluid alpha-fetoprotein results were obtained from the only laboratory performing the tests as a Statewide antenatal screening programme, and information on ultrasound screening from case notifications, hospital case records and medical practitioners who cared for the women.<h4>Subjects</h4>All 243 births and terminations of pregnancy with neural tube defects in South Australia in 1986-1991.<h4>Main outcome measures</h4>The sensitivity of individual screening methods and of all methods used, particularly for spina bifida.<h4>Results</h4>For pregnancies with neural tube defects screened by any method (serum alpha-fetoprotein, ultrasound or amniocentesis), 86% sensitivity was achieved. Ultrasound screening for anencephaly achieved 100% sensitivity even in low risk pregnancies, compared with 92% for serum alpha-fetoprotein. For spina bifida, the sensitivity of ultrasound screening increased with the level of risk in pregnancy: it was 60% in low risk pregnancies, which was equivalent to that of serum alpha-fetoprotein screening (64%); 89% in high risk pregnancies and 100% for women referred for confirmation of a suspected spina bifida by another ultrasonographer (chi 1(2) for trend = 23.49, P < 0.0001). Ultrasound screening in high risk pregnancies for spina bifida achieved higher sensitivity in teaching hospitals compared with other ultrasound services in the State (97% vs 65%), but sensitivity was equivalent for low risk pregnancies. It is estimated that, had the serum screening programme not been in place, the level of sensitivity achieved for spina bifida by ultrasound and amniocentesis would have been 62% compared with the actual situation of 76% with the programme in existence, a difference of nearly 15% (95% CI 2.5 to 26.7) (chi 1(2) = 5.45, P = 0.02).<h4>Conclusions</h4>Antenatal screening for neural tube defects in South Australia achieved a higher level of sensitivity with the maternal serum alpha-fetoprotein programme in place. We conclude that the serum screening programme should continue in South Australia pending a significant improvement in the sensitivity of routine ultrasound screening for spina bifida.
Keywords: Humans
Neural Tube Defects
Anencephaly
Encephalocele
Spinal Dysraphism
alpha-Fetoproteins
False Positive Reactions
Ultrasonography, Prenatal
Prenatal Diagnosis
Sensitivity and Specificity
Pregnancy
South Australia
Female
DOI: 10.1111/j.1471-0528.1995.tb11287.x
Published version: http://dx.doi.org/10.1111/j.1471-0528.1995.tb11287.x
Appears in Collections:Aurora harvest
Paediatrics publications

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.