Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/70989
Citations
Scopus Web of Science® Altmetric
?
?
Type: Journal article
Title: Selection of a cutoff value for real-time polymerase chain reaction results to fit a diagnostic purpose: analytical and epidemiologic approaches
Author: Caraguel, C.
Stryhn, H.
Gagne, N.
Dohoo, I.
Hammell, L.
Citation: Journal of Veterinary Diagnostic Investigation, 2011; 23(2):2-15
Publisher: Amer Assoc Veterinary Laboratory Diagnosticians Inc
Issue Date: 2011
ISSN: 1040-6387
1943-4936
Statement of
Responsibility: 
Charles G.B. Caraguel; Henrik Stryhn; Nellie Gagné; Ian R. Dohoo and K. Larry Hammell
Abstract: Diagnostic laboratories frequently select a subjective cutoff value for real-time amplification assays, above which a threshold cycle (Ct) value is deemed false. Commonly, higher Ct values are interpreted as amplification or fluorescence artifacts, or cross contaminations. Although the implementation of Ct cutoff might be reasonable, its justification and selection should be based on evidence. The current article reviewed evidence-based strategies to select Ct cutoffs grouped in analytical and epidemiologic approaches. Analytical strategies use criteria gathered during the assay development and include fluorescence threshold, reaction end-cycle, limit of detection, and artifact investigation. Variability in amplification efficacy across test runs may induce some instability in an intended Ct cutoff and requires some standardization or normalization procedures. Epidemiologic strategies use criteria based on either the probability or the cost of a false test result associated with a specified cutoff. Cutoffs, depending on the intended purpose of the test, can be selected graphically to minimize the probability of either false-positive or false-negative results by using two-graph receiver operating characteristics curves. The assay's diagnostic sensitivity and specificity may vary with the tested population, thus, the estimated two-graph receiver operating characteristics curve is population dependent and should be established for the targeted population. Although the selection of a cutoff based on misclassification cost depends on infection prevalence, the selection based on predictive values does not. To optimize the test average diagnostic performance, the Ct cutoff should be selected when diagnostic odds ratio is maximal. Epidemiologic approaches were illustrated by selecting Ct cutoffs for a real-time assay for Infectious salmon anemia virus.
Keywords: Cutoff
real-time
threshold cycle
two-graph receiver operating characteristics
Rights: Copyright © 2012 by American Association of Veterinary Laboratory Diagnosticians
DOI: 10.1177/104063871102300102
Published version: http://dx.doi.org/10.1177/104063871102300102
Appears in Collections:Animal and Veterinary Sciences publications
Aurora harvest

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.