Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/72540
Citations
Scopus Web of Science® Altmetric
?
?
Type: Journal article
Title: Label-free reflectometric interference microchip biosensor based on nanoporous alumina for detection of circulating tumour cells
Author: Kumeria, T.
Kurkuri, M.
Diener, K.
Parkinson, L.
Losic, D.
Citation: Biosensors and Bioelectronics, 2012; 35(1):167-173
Publisher: Elsevier Advanced Technology
Issue Date: 2012
ISSN: 0956-5663
1873-4235
Statement of
Responsibility: 
Tushar Kumeria, Mahaveer D. Kurkuri, Kerrilyn R. Diener, Luke Parkinson and Dusan Losic
Abstract: In this report, a label-free reflectometric interference spectroscopy (RIfS) based microchip biosensor for the detection of circulating tumour cells (CTCs) is demonstrated. Highly ordered nanoporous anodic aluminium oxide (AAO) fabricated by electrochemical anodization of aluminium foil was used as the RIfS sensing platform. Biotinylated anti-EpCAM antibody that specifically binds to human cancer cells of epithelial origin such as pancreatic cancer cells (PANC-1) was covalently attached to the AAO surface through multiple surface functionalization steps. Whole blood or phosphate buffer saline spiked with low numbers of pancreatic cancer cells were successfully detected by specially designed microfluidic device incorporating an AAO RIfS sensor, without labour intensive fluorescence labelling and/or pre-enhancement process. Our results show that the developed device is capable of selectively detecting of cancer cells, within a concentrations range of 1000-100,000 cells/mL, with a detection limit of <1000 cells/mL, a response time of <5 min and sample volume of 50 μL of. The presented RIfS method shows considerable promise for translation to a rapid and cost-effective point-of-care diagnostic device for the detection of CTCs in patients with metastatic cancer.
Keywords: Cell Line, Tumor
Humans
Aluminum Oxide
Cell Adhesion Molecules
Antibodies, Neoplasm
Antigens, Neoplasm
Microscopy, Electron, Scanning
Microfluidic Analytical Techniques
Spectrum Analysis
Equipment Design
Biosensing Techniques
Surface Properties
Porosity
Metal Nanoparticles
Neoplastic Cells, Circulating
Antibodies, Immobilized
Lab-On-A-Chip Devices
Limit of Detection
Epithelial Cell Adhesion Molecule
Rights: Crown Copyright © 2012 Published by Elsevier B.V. All rights reserved.
DOI: 10.1016/j.bios.2012.02.038
Published version: http://dx.doi.org/10.1016/j.bios.2012.02.038
Appears in Collections:Aurora harvest 5
Chemical Engineering publications

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.