Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/83058
Citations
Scopus Web of Science® Altmetric
?
?
Full metadata record
DC FieldValueLanguage
dc.contributor.authorIdris, Y.-
dc.contributor.authorOzbakkaloglu, T.-
dc.contributor.editorXu, B.-
dc.contributor.editorLi, H.-
dc.date.issued2013-
dc.identifier.citationAdvanced Materials Research, 2013 / Xu, B., Li, H. (ed./s), vol.743, pp.39-44-
dc.identifier.isbn9783037857533-
dc.identifier.issn1022-6680-
dc.identifier.issn1662-8985-
dc.identifier.urihttp://hdl.handle.net/2440/83058-
dc.description.abstractThis paper reports on part of an ongoing experimental program at The University of Adelaide on the seismic behavior of high-strength concrete (HSC)-filled fiber reinforced polymer (FRP) tubes (HSCFFTs). The results from three square concrete-filled FRP tube (CFFT) columns that were tested under combined constant axial compression and reversed-cyclic lateral loading are presented. The main parameters of the experimental study included the axial load level, concrete strength, and FRP tube corner radius. The results indicate that square HSCFFT columns are capable of developing very high inelastic deformation capacities under simulated seismic loading. The results also indicate that increasing the corner radius beyond a certain threshold value provides no increase in column lateral drift capacities. It was observed that column deformability decreased with an increase in axial load level (P/Po) and concrete compressive strength (fc). The results of the experimental program are presented together with a discussion on the influence of the main parameters on the seismic behavior of CFFT columns.-
dc.description.statementofresponsibilityYunita Idris and Togay Ozbakkaloglu-
dc.language.isoen-
dc.publisherTrans Tech Publications Ltd.-
dc.relation.ispartofseriesAdvanced Materials Research-
dc.rights© (2013) Trans Tech Publications-
dc.source.urihttp://dx.doi.org/10.4028/www.scientific.net/amr.743.39-
dc.subjectFibre Reinforced Polymer (FRP)-
dc.subjectHigh-Strength Concrete (HSC)-
dc.subjectColumn-
dc.subjectConfinement-
dc.subjectTubes-
dc.subjectLateral Drift-
dc.titleBehavior of high-strength concrete-filled FRP tube columns under simulated seismic loading: An experimental study-
dc.typeConference paper-
dc.contributor.conferenceInternational Conference on Building Materials and Structural Engineering (BMSE) (24 May 2013 - 25 May 2013 : Beijing)-
dc.identifier.doi10.4028/www.scientific.net/AMR.743.39-
dc.publisher.placeSwitzerland-
pubs.publication-statusPublished-
dc.identifier.orcidOzbakkaloglu, T. [0000-0003-3015-736X]-
Appears in Collections:Aurora harvest
Civil and Environmental Engineering publications

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.